4-Step Firing Schedule

Please note: the schedules below are guidelines only, not strict rules. Times and temperatures may be adjusted based on the nature of your project.
 
TACK Fuse
Segment
Ramp
(º F per hour)
Goal Temp.
(º F )
Hold Time
(minutes)
1
300
1150
30
2
400
1370
0
3
9999*
950
60
4
150
800
10
*As fast as possible.
CONTOUR Fuse
Segment
Ramp
(º F per hour)
Goal Temp.
(º F )
Hold Time
(minutes)
1
300
1150
30
2
400
1440
5
3
9999*
950
60
4
150
800
10
*As fast as possible.
FULL Fuse
Segment
Ramp
(º F per hour)
Goal Temp.
(º F )
Hold Time
(minutes)
1
300
1150
30
2
400
1475
10
3
9999*
950
60
4
150
800
10
*As fast as possible.
SLUMP
Segment
Ramp
(º F per hour)
Goal Temp.
(º F )
Hold Time
(minutes)
1
150
300
15
2
300
1235
15
3
9999*
950
60
4
150
800
10
*As fast as possible.
 

© 2009 Spectrum Glass Company, Inc. PO Box 646 Woodinville, WA 98072 USA Phone: 425-483-6699 Fax: 425-483-9007 E-mail: Hotglass@System 96.com

All rights reserved. Spectrum, System 96 are registered trademarks of Spectrum Glass Company, Inc. Spirit and OpalArt are trademarks of Spectrum Glass Company.